混凝土生产过程中存在的浪费,主要是混凝土搅拌站生产人员没法掌握车辆搅拌罐中实际物料的质量,这也是水稳搅拌站发挥作用的时候。那水稳搅拌站进行空气处理组件时会如何?
The waste in the production process of concrete is mainly that the production personnel of concrete mixing station can not master the quality of the actual material in the vehicle mixing tank, which is also the time when the water stable mixing station plays a role. What about the water stable mixing plant for air treatment components?
油水分离器的故障中又分为,滤芯堵塞、破损,排污阀的运动部件动件不灵活等情况。工作中要经常清洗滤芯,除去排污器内的油污和杂质。济南水稳搅拌站调压阀的故障与上述“减压阀的故障”相同。油雾器的故障现象有:不滴油、油杯底部沉积有水分、油杯口的密封圈损坏等。
The faults of oil-water separator can be divided into blockage and damage of filter element, inflexible moving parts of sewage valve and so on. Work often to clean the filter, remove the oil pollution and impurities in the sewage. The failure of the pressure regulating valve of Ji 'nan water stability mixing plant is the same as the above “failure of the pressure reducing valve”. The fault phenomena of oil mist include: no oil dripping, water deposition at the bottom of the oil cup, damage of the sealing ring at the mouth of the oil cup, etc.
当油雾器不滴油时,应检查进气口的气流量是否低于起雾流量,是否漏气,油量调节针阀是否堵塞等;如果油杯底部沉积了水分,应及时排除;当密封圈损坏时,应及时更换。由于气缸装配不当和长期使用,气动执行元件(气缸)易发生内、外泄漏,输出力不足和动作不平稳,缓冲效果不好,活塞杆和缸盖损坏等故障现象。
When the oil mist does not drop oil, it should be checked whether the air flow of the air inlet is lower than the fog flow, whether the air leakage, oil regulating needle valve is blocked, etc.; If water is deposited at the bottom of the oil cup, it should be removed in time; When the sealing ring is damaged, it should be replaced in time. Due to improper cylinder assembly and long-term use, pneumatic actuator (cylinder) prone to internal and external leakage, insufficient output force and action is not smooth, the buffer effect is not good, piston rod and cylinder head damage and other fault phenomena.
济南水稳搅拌站压力调不高,往往是因调压弹簧断裂或膜片破裂而造成的,需要换掉;压力上升缓慢,一般是因过滤网被堵塞引起的,应拆下清洗。管路接头泄漏和软管破裂时可从声音上来判断漏气的部位,应及时修补或更换。
Ji 'nan water stability mixing station pressure is not high, often due to pressure spring fracture or diaphragm rupture caused by the need to replace; The pressure rises slowly, generally because the filter is blocked, should be removed and cleaned. When the pipe joint leaks or the hose breaks, you can determine the air leakage part by the sound, and repair or replace it in time.